• 0000172820 Induline DW 601/35 Aqua Stopp ML

    Article No. 169203

    Induline DW-601 Aqua Stop

    Opaque, water-based intermediate and finishing coat for spraying

    Button EN 71/3 Schaukelpferd Button Aqua Stopp Button remmers-mix Button VOC FR A+
    Colour: special colours | 1692
    Colour: special colours | 1692
    Please choose a colour

    Product specifications

    On delivery

    Binder special acrylate/PU polymers
    Density (20°C) approx. 1.15 g/cm³
    Odour characteristic
    Degree of gloss matt/silk matt/silk gloss
    Pigmentation titanium dioxide, various organic/inorganic pigments
    Viscosity approx. 2000 mPa·s

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use indoors and outdoors
    • for dimensionally stable elements
    • For professional users only
    • For use on interior and exterior wood
    • Soft and hard woods
    • Dimensionally stable wood building elements: e.g. windows and doors
    • Intermediate and finishing coats
    • Single coat and multi-coat procedure

    Properties

    • Water-based
    • Excellent flow properties
    • High hiding power
    • Low waiting time until material is fit for use
    • Increased block resistance
    • Early resistance to water: minimises the risk of damage, e.g. to "winter constructions"
    • Supports sealing when used with suitable primer and intermediate coatings
    • Pleasant feel
    • Good resistance to yellowing and chalking
    • Special combination of binding agents creates an extremely hard-wearing surface
    • Very good hail resistance: elasticity at low temperatures
    • Very low tendency to develop temporary water stains
    • Low soiling tendency
    • Preparation
      • Substrate requirements

        The substrate must be clean, dry, free of dust, grease and loose substances, and prepared in the correct manner.

        Dimensionally stable wood building elements: wood moisture content 11-15%

      • Preparations

        If necessary, impregnate non-resistant woods with a wood preservative*.

        Pre-treat using a suitable primer & intermediate coat and carry out intermediate sanding if necessary.

        If necessary, protect parapet joints with Induline V-Joint Protection or Induline AF-920.

    • Application
      • Stir before use
      • Airless/airmix spraying
      • Temperature of the material, air and substrate: from min. +15 °C to max. +30 °C
      • Dynflow (fully automatic coating plant)
      • elektrostatische Lackierung (E-Statik)
      • Application requirements

        Temperature of the material, air and substrate: from min. +15 °C to max. +30 °C.

      • The values given are based on undiluted material. The best spraying pattern is achieved if the material has a temperature of 15-20 °C.

        Ensure good ventilation.

        Airless spraying: nozzle size: 0.28-0.33 mm; material pressure: 70-90 bar.

        Air-mix spraying: nozzle size: 0.28-0.33 mm; material pressure: 70-90 bar, atomiser air pressure 1-2 bar.

        Seal opened containers well and use contents as soon as possible.

    • Application instructions
      • Drying time: can be worked over after 4 h
      • Check colour, adhesion and compatibility with the substrate by setting up a trial area.

        Do not use in direct sunlight or at temperatures below +15 °C or above +30 °C.

        Recycling is possible via the standard channels. Liaise with Remmers Technical Service if coatings have been mixed.

        To prevent coloured substances contained in the wood from showing through, use a suitable primer and intermediate coating with a sealing effect on white or light-coloured surfaces.

        With water based coating systems, there is always a residual risk that substances contained in the wood will cause discoloration.

        The system finder on our website www.remmers.de contains coating recommendations for specific wood types to be used when treating windows and exterior doors.

        To avoid thicker coats, e.g. in the case of full-tone colours, pretreat with translucent rather than white primer. Then add the coloured topcoat as the intermediate coat.

      • Drying

        Dust dry: after approx. 1 hour Ready for sanding and next coat: after approx. 4 hours (at 23 °C and 50% RH) When forced drying takes place, ready for sanding and next coat: 20 minutes flash-off time (at approx. 20 °C and 65-75% RH) / 75 minutes drying time (approx. 45 °C, 1 m/s air circulation) / 20 minutes cooling time

      • Thinning

        If necessary with water (max. 5%).

    • Working tools / cleaning
      • Airless/airmix spraying
      • Dynflow (fully automatic coating plant)
      • elektrostatische Lackierung (E-Statik)
      • Hand spray guns, automatic spraying equipment

      • Clean tools with water or Aqua RK-898 Cleaning Concentrate immediately after use.

        Ensure that any residue from cleaning is disposed of correctly.

    • Storage / shelf life
      • Shelf-life 24 months
      • Store frost-free and cool / protect for moisture / close containers
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 24 months.

    • Usage
      • Approx. 150 ml - 300 ml / m² per layer applied
      • 150-300 ml/m² (plus spray loss) (corresponds to wet film thickness of 150-300 μm, dry film thickness of 60-120 μm) Some figures may differ depending on the colour.

    • General information
      • Sealing:

        Sealing compounds must be compatible with the coating and may only be applied once the coating has dried thoroughly.

        Only use sealing profiles that are free of plasticisers.

        Where the coating substances used are rich in colour, colour rub-off may occur, e.g. during cleaning. These effects are temporary and sporadic and do not impact the quality of the product in any way. Please see the technical information contained in TI 5.12 "Paint chalking".

        Production of a brushing quality:

        Add 10 - 20% water to this product to obtain a coating that can be applied by brush for touch-ups.

        Care and maintenance:

        Wood is subjected to great climatic and environmental stresses when outdoors. The coat is susceptible to the processes of natural ageing, wear and decomposition. Decomposition takes place at different speeds, depending on the stress (weak, average, strong) placed on the wood building element. Weathering stages may vary according to the part or element affected. To give wood the longest and best possible protection it is advisable to examine surfaces every year. Any damage found should be addressed immediately after cleaning.

        For cleaning and care, we recommend the care set for windows (2745) and doors (2746).

        We recommend that reconditioning coats be applied using Aqua AG-26 All Primer (7147) and Aqua DL-65 Opaque Top PU (7200) or Aqua VL-66/sm Venti-Coat 3in1 (7090)

        Observe current standards and guidelines for coating wood building elements outdoors (Codes of Practice issued by the German Association of Window and Facade Manufacturers (VFF), Code of Practice No. 18 issued by the German Federal Committee for Paint and the Protection of Material Assets (BFS), guidelines issued by the German Lacquer and Printing Ink Association (VdL) and ift guidelines issued by the Institut für Fenstertechnik).

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.