Article No. 652913
High-quality, pure acrylate facade paint
Product specifications
(DIN EN ISO 7783-2) sd ≤ 0.3 m *
(DIN EN 1062-6) sd ≥ 252 m *
(DIN EN 1062-3) w ≤ 0.1 kg/(m² ∙ h0.5) *
* These values refer to a two-layer coating with a dry film thickness of 180 μm.
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- Facades and concrete surfaces
- Surface protection systems for concrete in accordance with DIN EN 1504/DIN V 18026
Remmers OS-B / OS 2 system:
Primer H (Impregnation Primer ) + Color PA (Concrete Acrylic)
Remmers OS-C / OS 4 system:
Color PA Fill (OS Concre Fill) + Color PA (Concrete Acrylic)
Remmers OS-C / OS 4 system:
Betofix Fill (Betofix Filler) + Color PA (Concrete Acrylic)
Properties
- Carbonation-inhibiting sd CO2 : ≥ 252 m
- Highly water-repelling w ≤ 0.1 kg/(m² ∙ h0.5)
- Water vapour permeable sd < 0.3 m
- Weather resistant
- Free from plasticisers
- Free of aromatic compounds
- Very good hiding power
- Colour stable
- Listed in BASt
- Tested in accordance with DIN EN 1504-2
-
Preparation
-
Substrate requirements
Dry, clean, free of dust and cracks (except hairline cracks) and capable of supporting a load.
Free of aggressive salts.
-
Preparations
Remove any old coatings not capable of supporting a load, making sure not to leave any residue.
Use Primer Hydro HF to prime mineral substrates capable of supporting a load.
Use Primer Hydro HF to prime any sanding, firmly adhering substrates.
-
-
Application
-
Stir well.
Coat the surface using a suitable tool.
Apply the material in 2 or 3 coats, depending on the condition of the substrate.
Wait at least 8 hours between coats.
-
Application instructions
-
Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.
When coating continuous surfaces, only use materials with the same batch number.
Intensive colours, such as yellow, red, etc. may have a lower hiding power due to their pigments. Apply an additional coat if required.
Protect freshly treated surfaces from driving rain, wind, sunlight and condensation.
-
-
Working tools / cleaning
-
Brush, flat brush, lambskin roller, airless spraying equipment.
-
Paintbrush, flat brush, lamb's wool roller, airless spraying equipment
Clean tools, equipment and any splashed material immediately with water while still fresh.
-
Storage / shelf life
-
If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.
-
Usage
-
Approx. 200 ml/m² per coat depending on the condition of the substrate
-
The application rate depends on the absorbency of the surface
Apply to a large enough trial area to determine the precise amount required.
For information on the surface protection systems OS 2 and OS 4, see the relevant test report
-
General information
-
Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.
The relevant test certificates must be observed when planning and carrying out work.
Always set up a trial area/trial areas first.
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-
-
Safety / regulations
-
For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.
-