• Concrete Acrylic
    • Concrete Acrylic

    Article No. 650213

    Color PA

    High-quality, pure acrylate facade paint

    Colour: pebble grey (RAL 7032) | 6502
    Colour: pebble grey (RAL 7032) | 6502
    Please choose a colour
    Size / Quantity

    Product specifications

    Binder 100% pure acrylate
    Density approx. 1.3 g/cm³
    pH value 9
    Pigmentation lightfast, alkali resistant oxide pigments, or titanium dioxide
    Viscosity approx. 3000 mPa∙s
    Extender mineral fillers

    Once fully cured

    Degree of gloss silk matt
    Water vapour permeability
    (DIN EN ISO 7783-2)
    sd ≤ 0.3 m *
    CO2 permeability
    (DIN EN 1062-6)
    sd ≥ 252 m *
    Water absorption coefficient
    (DIN EN 1062-3)
    w ≤ 0.1 kg/(m² ∙ h0.5) *
    Surface structure smooth
    Weather resistance very good

    * These values refer to a two-layer coating with a dry film thickness of 180 μm.

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use indoors and outdoors
    • Facades and concrete surfaces
    • Surface protection systems for concrete in accordance with DIN EN 1504/DIN V 18026
      Remmers OS-B / OS 2 system:
      Primer H (Impregnation Primer ) + Color PA (Concrete Acrylic)
      Remmers OS-C / OS 4 system:
      Color PA Fill (OS Concre Fill) + Color PA (Concrete Acrylic)
      Remmers OS-C / OS 4 system:
      Betofix Fill (Betofix Filler) + Color PA (Concrete Acrylic)

    Properties

    • Water-based
    • Carbonation-inhibiting sd CO2 : ≥ 252 m
    • Highly water-repelling w ≤ 0.1 kg/(m² ∙ h0.5)
    • Water vapour permeable sd < 0.3 m
    • Weather resistant
    • Free from plasticisers
    • Free of aromatic compounds
    • Very good hiding power
    • Colour stable
    • Listed in BASt
    • Tested in accordance with DIN EN 1504-2
    • Preparation
      • Substrate requirements

        Dry, clean, free of dust and cracks (except hairline cracks) and capable of supporting a load.

        Free of aggressive salts.

      • Preparations

        Remove any old coatings not capable of supporting a load, making sure not to leave any residue.

        Use Primer Hydro HF to prime mineral substrates capable of supporting a load.

        Use Primer Hydro HF to prime any sanding, firmly adhering substrates.

    • Application
      • By brush / By roller / Airless/airmix spraying
      • Application temperature: min. 5 °C max. 25 °C
      • Stir well.

        Coat the surface using a suitable tool.

        Apply the material in 2 or 3 coats, depending on the condition of the substrate.

        Wait at least 8 hours between coats.

    • Application instructions
      • Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.

        When coating continuous surfaces, only use materials with the same batch number.

        Intensive colours, such as yellow, red, etc. may have a lower hiding power due to their pigments. Apply an additional coat if required.

        Protect freshly treated surfaces from driving rain, wind, sunlight and condensation.

    • Working tools / cleaning
      • By brush / By roller / Airless/airmix spraying
      • Brush, flat brush, lambskin roller, airless spraying equipment.

      • Paintbrush, flat brush, lamb's wool roller, airless spraying equipment

        Clean tools, equipment and any splashed material immediately with water while still fresh.

    • Storage / shelf life
      • Store frost-free and cool / protect for moisture / close containers
      • Shelf-life 12 months
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.

    • Usage
      • Approx. 200 ml / m² per layer applied
      • Approx. 200 ml/m² per coat depending on the condition of the substrate

      • The application rate depends on the absorbency of the surface

        Apply to a large enough trial area to determine the precise amount required.

        For information on the surface protection systems OS 2 and OS 4, see the relevant test report

    • General information
      • Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.

        The relevant test certificates must be observed when planning and carrying out work.

        Always set up a trial area/trial areas first.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.

    Tools, accessories and PPE