Article No. 28346505
High-build, tintable intermediate coating for spray application

Downloads & documents
Product specifications
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- For use on interior and exterior wood
- Soft and hard woods
- Dimensionally stable wood building elements: e.g. doors, windows and shutters
- For use by professionals
Properties
- High stability
- Excellent flow properties
- Good build on the surface
- Good hiding power
- Good sanding properties
- Not suitable for use on woods containing high levels of active substances
-
Preparation
-
Substrate requirements
The substrate must be clean, dry, free of dust, grease and loose substances, and prepared in the correct manner.
Dimensionally stable wood building elements: wood moisture content 11-15%
-
Preparations
Prime wood surfaces.
If necessary, protect parapet joints with Induline V-Joint Protection or Induline AF-920.
-
-
Application instructions
-
If necessary, check compatibility with the substrate and sealing effect by applying a trial coat.
Before coating technically modified woods and wood-based materials, apply the product to a trial surface and conduct a suitability test on the desired area of use.
Prior to full application, please apply a test coat to a sample area under practical conditions using the desired system, then test or examine the surface properties.
Ensure good ventilation.
With water based coating systems, there is always a residual risk that substances contained in the wood will cause discolouration.
Bleeding resin is a natural phenomenon and cannot be prevented by coating measures, see BFS Code of Practice No. 18.
The product's sealing effect may be impaired if it is diluted too thinly, if the wood is too wet or if the recommended coating sequence, application volumes and drying times are not observed.
The system finder on our website www.remmers.com contains coating recommendations for specific wood types to be used when treating windows and exterior doors.
-
Drying
Can be sanded and overcoated: after approx. 4 hours
(it is recommended to leave the coating to dry overnight so that the film can fully harden)
(at 23 °C and 50% RH)Low temperatures, poor ventilation and high humidity delay drying.
-
Thinning
Dilute with water if necessary (max. 5%)
-
Working tools / cleaning
-
Hand spray gun, automatic spraying equipment, flow cup gun
Clean tools with water or Aqua RK-898 Cleaning Concentrate immediately after use.
Ensure that any residue from cleaning is disposed of correctly.
-
Storage / shelf life
-
If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.
-
Usage
-
150 - 200 ml/m² per coat
(equivalent to a wet film thickness of approx. 150-200 μm, dry film thickness approx. 70-90 μm)
-
General information
-
Sealing compounds must be compatible with the coating and may only be applied once the coating has dried thoroughly.
Only use sealing profiles that are free of plasticisers.
Wood building elements which have been treated with an intermediate coating should not be exposed to weathering until a finishing coat has been applied.
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-
-
Safety / regulations
-
For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.
-