    Article No. 072705

    Kiesol C

    Solvent-free silane cream for horizontal barriers against rising masonry damp

    Button WTA blau

    Product specifications

    On delivery

    Appearance/colour Milky, white
    Density (20°C) Approx. 0.89 g/cm³
    Flash point > 100 °C
    Consistency Cream form
    Active ingredient content ≥ 80% by weight

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use indoors and outdoors
    • Porous, mineral building materials such as clay brick, sandstone and sand-lime brick
    • Subsequent horizontal waterproofing of masonry under low pressure up to a degree of moisture penetration of 95%

    Properties

    • Water-based
    • Water repellent
    • Solvent-free
    • Active ingredient content 80%
    • Excellent penetration
    • High yielding
    • Optimised for injection under gravity
    • Preparation
      • Substrate requirements

        Drilling channel must be free of drill dust.

      • Preparations

        Creating boreholes: Single row, diameter 12 mm, spacing 12 cm, horizontal plane, borehole depth up to approx. 2 cm from end of wall.

        For walls of thickness > 0.6 m, drill on both sides if necessary.

    • Application
      • Sealant gun / Injection hose / Desoi piston pump EP-60
      • Application temperature: min. 5 °C max. 30 °C
      • Application requirements

        Temperature of the material, air and substrate: from min. +5 °C to max. +30 °C.

      • Inject material using suitable injection apparatus depending on the packaging type.

        Do not fill the last 2 cm of the boreholes with cream.

    • Application instructions
      • Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.

        Then, apply surface waterproofing to at least 30 cm above and below the row of boreholes. Include adjacent components if necessary.

        Close boreholes on the same day using WP DS Level (Art. 0426).

        For the subsequent surface sealing, it is recommended to apply an additional coat of WP DS Level (Art. 0426) in the region of the row of boreholes.

        Temporary discolouration of the surface may occur in the areas in which the material propagates, in particular on fair-faced masonry.

        We recommend to set up sample areas.

    • Working tools / cleaning
      • Sealant gun / Injection hose / Desoi piston pump EP-60
      • Sealant gun, Injection lance for 550 ml, Injection hose for 550 ml, Injection set for 550 ml, Desoi piston pump EP-60 for 10 l politainer, Low-pressure equipment, conveying equipment and spraying equipment with suitable injection lance

      • Clean tools, equipment and any splashed material immediately with water while still fresh.

        Ensure that any residue from cleaning is disposed of correctly.

    • Storage / shelf life
      • Shelf-life 12 months
      • Store frost-free and cool / protect for moisture / close containers
      • In unopened original containers, stored in a cool, dry place protected from frost
        - 550 ml tube bag with screw cap
        - 10 l politainer
        - 5 l, 15 l plastic bucket will keep for at least 12 months.

    • Usage
      • Depending on the application / m²
      • For details see application rate table under application examples

      • Application rates will be higher for hollow masonry.

    • Application examples
      • Application rate equals the borehole volume to be filled plus a safety margin.
        Borehole diameter:
        12 mm
        Wall thickness: 10 cm
        Borehole depth: approx. 8 cm
        Application rate* per m: 8.3 holes


        approx. 80 ml

        Wall thickness: 11.5 cm
        Borehole depth: approx. 9.5 cm
        Application rate* per m: 8.3 holes


        approx. 100 ml

        Wall thickness: 24 cm
        Borehole depth: approx. 22 cm
        Application rate* per m: 8.3 holes


        approx. 230 ml

        Wall thickness: 36 cm
        Borehole depth: approx. 34 cm
        Application rate* per m: 8.3 holes


        approx. 350 ml

        Wall thickness: 42 cm
        Borehole depth: approx. 40 cm
        Application rate* per m: 8.3 holes


        approx. 415 ml

        * 10% safety margin included

    • General information
      • Not suitable for aerated concrete or loam building materials.

        Not suitable for fresh joint mortar.

        A test of effectiveness needs to be carried out on carbonaceous natural stone.

        The relevant test certificates must be observed when planning and carrying out work.

        The applicable regulations and legal requirements must be observed.

        Information on planning injection processes with and processing certified injection materials against capillary moisture transport can be found in WTA Leaflet 4-10-15 and must be taken into account.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.