    Product specifications

    Appearance/colour Milky, white
    Density (20°C) Approx. 0.94 g/cm³
    Flash point > 100 °C
    Consistency Cream form

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use indoors and outdoors
    • Porous, mineral building materials such as clay brick, sandstone and sand-lime brick
    • Subsequent horizontal waterproofing of masonry under low pressure up to a degree of moisture penetration of 95%

    Properties

    • Water-based
    • New inverse formulation for faster action
    • Silane/siloxane-based
    • Excellent penetration
    • Optimised for injection under gravity
    • High yielding
    • Water repellent
    • Preparation
      • Substrate requirements

        Drilling channel must be free of drill dust.

      • Preparations

        Creating drill holes:
        Single row, diameter 12 mm, spacing 12 cm, horizontal plane, hole depth up to approx. 2 cm from end of wall.

        For walls of thickness > 0.6 m, drill on both sides if necessary.

    • Application
      • Application temperature: min. 5 °C max. 30 °C
      • Sealant gun / Injection hose / Desoi piston pump EP-60
      • Inject material using suitable injection apparatus depending on the packaging type.

        Do not fill the last 2 cm of the drill holes with cream.

    • Application instructions
      • Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.

        Close drill holes on the same day using WP DS Level (Art. 0426).

        Temporary discolouration of the surface may occur in the areas in which the material propagates, in particular on fair-faced masonry.

        For the subsequent surface sealing, it is recommended to apply an additional coat of WP DS Level (Art. 0426) in the region of the row of drill holes.

        Then, apply surface waterproofing to at least 30 cm above and below the row of drill holes. Include adjacent components if necessary.

        We recommend setting up trial areas.

    • Working tools / cleaning
      • Sealant gun / Injection hose / Desoi piston pump EP-60
      • Sealant gun,
        Injection lance for 550 ml,
        Injection hose for 550 ml,
        Injection set for 550 ml,
        Desoi PowerPump 70 for 10 l politainer,
        Low-pressure, conveying and spraying equipment with suitable injection lance

      • Clean tools and remove spilled material while it is still wet using Aqua RK-898 Cleaning Concentrate (3868) or Thinner V 101 (0978).

        If the machine is to be left unused for longer periods, drain it and clean with RK-898 or Thinner V101.

        Ensure that any residue from cleaning is disposed of correctly.

        Please contact Remmers Technical Service (phone +49 5432 83900) before applying with machine processing.

    • Storage / shelf life
      • Store frost-free and cool / protect for moisture / close containers
      • Shelf-life 12 months
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.

        Use the contents of open containers as quickly as possible.

    • Usage
      • Depending on the application / m²
      • For details see application rate table under application examples

      • Application rates will be higher for hollow masonry.

    • Application examples
      • Application rate equals the borehole volume to be filled plus a safety margin.

        Borehole diameter: 12 mm
        Borehole spacing:         12 cm, i.e. 8.3 holes per m

        Wall thickness:        
        Borehole depth:        
        Application rate* per m:                    
        10 cm
        approx. 8 cm
        approx. 80 ml
        11.5 cm
        approx. 9.5 cm

        approx. 100 ml

        24 cm

        approx. 22 cm

        approx. 230 ml

        36 cm
        approx. 34 cm
        approx. 350 ml
        42 cm

        approx. 40 cm

        approx. 415 ml

        *10% safety margin included

    • General information
      • Not suitable for aerated concrete, gypsum and clay building materials.

        Not suitable for new grouting mortar.

        A test of effectiveness needs to be carried out on carbonaceous natural stone.

        The relevant test certificates must be observed when planning and carrying out work.

        The applicable regulations and legal requirements must be observed.

        Information on planning injection processes with and processing certified injection materials against capillary moisture transport can be found in WTA Code of Practice 4-10 and must be taken into account.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.