Article No. 073105
Solvent-free, hydrophobic impregnation for concrete. Suitable for constructions such as overpasses, tunnels and bridges. Satisfies RWS RTD1002
Product specifications
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- Deep hydrophobising of concrete and reinforced concrete in bridge, road and building construction
- Protects against the ingress of de-icing salt
- Protects against damage caused by frost and de-icing salt
Properties
- Satisfies RWS RTD1002
- Improves resistance to frost and de-icing salts
- Repels water
- Enables water vapour diffusion
- Highly concentrated (approx. 99% active ingredient content)
- Alkali-resistant
- Excellent long-term effect
- Outstanding penetration
- Solvent-free
- Suitable under asphalt
- Meets the standard EN 1504-2
- PFAS-free formulation
-
Preparation
-
Substrate requirements
The substrate must be clean, dry, capable of bearing a load, and free from substances that may impair adhesion (oil, grease, wax).
-
Preparations
Any construction defects such as cracks, cracked joints, defective connections, rising damp and hygroscopic moisture must be remedied in advance.
Perform any necessary cleaning gently, e.g. by spraying with cold or warm water or by steam-cleaning; use soft whirl jet technology or Remmers cleaning products (e.g. Traffic Film Remover (0671), Clean FP (0666), Clean AC (0672), Combi WR (0675)) on tough stains.
-
-
Application
-
Apply the primer abundantly by flow coating without pressure (avoid misting), so that a 30 - 50 cm long liquid film flows down the surface.
Apply horizontally on one section at a time, moving from top to bottom, and immediately go over with a wide brush.
Repeat the application several (at least two) times (wet on damp) until no further material is absorbed by the substrate.On surfaces where spray application is not possible, apply using a well-saturated brush.
-
Application instructions
-
In order to ensure that the setting of the cement is not disrupted, concrete should be hydrophobised no earlier than four weeks after production.
Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.
Protect freshly treated surfaces from driving rain, wind, sunlight and condensation.
Use an absorbent sponge to remove excess impregnation agent after 30 minutes if required.
-
-
Working tools / cleaning
-
Non-corroding low-pressure conveying and spraying equipment, liquid pumps, paintbrush and flat brush.
Tools must be clean and dry.
Clean tools with an alcohol-based cleaner after use and before long pauses in work.
-
-
Storage / shelf life
-
If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.
Use the contents of open containers as quickly as possible.
-
Usage
-
Depending on the porosity: approx. 0.3 - 0.5 l/m²
The amount of impregnation agent required must be determined on a sufficiently large trial area (1-2 m²).
-
General information
-
Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.
The relevant test certificates must be observed when planning and carrying out work.
Water must not be allowed to penetrate behind the hydrophobized zone.
The level of absorption is crucial for the impregnation agent to work at its best. This depends on the respective pore volume and moisture content of the building material.
Carry out a quantitative analysis of aggressive salts if there are any salts present that could damage building materials.
High concentrations of harmful salts can cause major structural damage that impregnation cannot prevent.
Testing effectiveness:
The water absorption of mineral building materials can be determined using the Funcosil Test Tube developed by Professor Karsten (Funcosil Facade Testing Kit, article no. 4954).
Testing can only be carried out at the earliest 6 weeks after application.Always set up a trial area/trial areas first.
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not pour liquid coating or residues down the drain, even when cleaning tools used for applying the coating.
-
-
Safety / regulations
-
For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.
-