• Funcosil FC Plus
  • REM_0000071213_Funcosil_FC_Plus_ML.tif
    • Funcosil FC Plus
    • REM_0000071213_Funcosil_FC_Plus_ML.tif

    Article No. 071201

    Funcosil FC Plus

    Hydrophobising, colour intensifying impregnation in cream form on a silane/siloxane base

    Brochures and Catalogues

    product.brochures.loading

    Product specifications

    Appearance Milky, white, creamy
    Density (20°C) Approx. 0.86
    Flash point > 61
    pH value Approx. 7.0 neutral
    Active ingredient Silane/siloxane
    Active ingredient content, % by mass Approx. 40
    Carrier material De-aromatised hydrocarbons/water

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use outdoors
    • Protection of facades against driving rain
    • Reduces susceptibility to dirt and green discolouration
    • Porous, mineral building materials such as fired and sand-lime brick, clinker and render
    • Supplementary measure for energy-oriented renovation, in particular when retrofitting cavity and interior insulation

    Properties

    • Repels water
    • Enables water vapour diffusion
    • Colour intensifying
    • Outstanding penetration
    • UV-resistant
    • Alkali-resistant
    • Excellent long-term effect
    • Can be applied sparingly, with absolute precision and with no losses
    • Quickly becomes rain-proof, approx. 60 minutes after application
    • Preparation
      • Substrate requirements

        The substrate must be clean, dust-free and dry.

      • Preparations

        Any construction defects such as cracks, cracked joints, defective connections, rising damp and hygroscopic moisture must be remedied in advance.

        Perform any necessary cleaning gently, e.g. by spraying with cold or warm water or by steam-cleaning; use rotec soft whirl jet technology or Remmers cleaning products (e.g. Traffic Film Remover (0671), Clean FP (0666), Clean AC (0672), Combi WR (0675)) on tough stains.

    • Application
      • Application temperature: min. 10 °C max. 25 °C
      • By brush / By roller
      • Use a suitable tool to apply the impregnating agent crosswise.

    • Application instructions
      • Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.

        Protect freshly treated surfaces from driving rain, wind, sunlight and condensation.

        Remove any excess impregnation agent within 1 hour using V 101 thinner.

    • Working tools / cleaning
      • By brush / By roller
      • Long-pile lamb's wool roller, paintbrush.

      • Tools must be clean and dry.

        Clean tools with water after use and before any lengthy interruptions to work.

    • Storage / shelf life
      • Store frost-free and cool / protect for moisture / close containers
      • Shelf-life 12 months
      • Use the contents of open containers as quickly as possible.

        If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.

    • Usage
      • Total application/absorption rate 150 ml - 200 ml Total / m²
      • Depending on the porosity, in one coat: approx. 0.15 - 0.20 l/m²

      • Apply to a large enough trial surface (1-2 m²) to determine the precise amount of impregnation agent required.

    • General information
      • Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.

        The relevant test certificates must be observed when planning and carrying out work.

        Water must not be allowed to penetrate behind the hydrophobized zone.

        Carry out a quantitative analysis of aggressive salts if there are any salts present that could damage building materials.

        High concentrations of harmful salts can cause major structural damage that impregnation cannot prevent.

        The level of absorption is crucial for the impregnation agent to work at its best. This depends on the respective pore volume and moisture content of the building material.

        Testing effectiveness:


        The water absorption of mineral building materials can be determined using the Funcosil Test Tube developed by Professor Karsten (Funcosil Facade Testing Kit, article no. 4954).

        Testing can only be carried out at the earliest 6 weeks after application.

        Substrates with very low absorbency and highly textured surfaces should be treated with a liquid impregnation agent.

        A test of effectiveness needs to be carried out on carbonaceous natural stone.

        Always set up a trial area/trial areas first.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    Possible system products

    Tools, accessories and PPE