Article No. 024305
Capillary active polyurethane rigid foam panel for creating highly insulating, diffusion-capable interior insulation with capillary moisture transport

Product specifications
On delivery
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- Mould control and prevention in existing buildings
- Implementation of the hygienic minimum heat insulation level in existing buildings
- Improving the room climate by increasing the wall surface temperature
Properties
- Excellent thermal insulation
- Water vapour permeable
- Capillary-active
- Thermal conductivity (nominal value) approx. 0.031 W/(m•K)
- Low construction height
- Easy to apply
- Thermal insulation material according to DIN 4108-10
-
Preparation
-
Substrate requirements
The substrate must be clean and capable of bearing a load.
The substrate must be level.
-
Preparations
Level off and even out highly uneven substrates – use SP Level to close up joints and even out surfaces.
-
-
Application
-
Pre-wet absorbent substrates.
Apply iQ Fix to the substrate as a scratch coat.
Using a notched scraper, apply iQ Fix wet-on-wet to the rear face of the panel and the substrate.
Position and press on the boards from the bottom up.
Align using a floating rule.
-
Application instructions
-
Mark the desired dimensions on the board.
Cut using a jigsaw or hand-held circular saw.
Rework the cut edges with a rasp or file if necessary.
Make sure that the panels are correctly aligned (the side marked "plaster side" must be visible after application).
Avoid cross joints.
Make sure that full-surface bonding is achieved.
-
-
Working tools / cleaning
-
Cutter knife and jigsaw
-
Storage / shelf life
-
Dry and frost-free.
-
Usage
-
Approx. 1.4 panels/m²
-
General information
-
Deviations from applicable regulations must be agreed separately.
-
-
Disposal instructions
-
The product must be disposed of in accordance with the official regulations.
-