• Default Package Display_GB

    Article No. 286106

    Epoxy Color Joint EP

    Grouting material for ceramic coverings

    Colour: grey | 2861
    Size / Quantity

    Product specifications

    Component A

    Density (25 °C) 1.57 g/cm²

    Component B

    Density (25 °C) 0.96 g/cm²

    Mixture

    Density (25 °C) 1.40 g/cm²

    Once fully cured

    Flexural tensile strength after 7 days > 18 N/mm²
    Compressive strength after 7 days approx. 45 N/mm²
    Adhesive pull strength > 1.5 N/mm²

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • New grouting and re-grouting of ceramic wall and floor coverings, glass blocks etc. in the sanitary and hygiene sector.

    Properties

    • Thixotropic
    • Resistant to chemicals
    • Water emulsifiable
    • Preparation
      • Substrate requirements

        The substrate must be firm, dimensionally stable, capable of bearing loads and free of loose constituents, dust, oil, grease, rubber marks and other substances that could interfere with adhesion.

        When reworking old joints, sandy and crumbly grout, as well as grease, oil and other residues must be completely removed.

    • Preparation
      • Mixing ratio comp. A 8.5 : comp. B 1
      • Mixing time 2 min
      • Combination container

        Add the entire quantity of the hardener (component B) to the base compound (component A).

        Mix thoroughly with a slow-speed electric mixer
        (approx. 300 - 400 rpm).

        The mixing time must be at least 2 minutes.

        Pour the mixture into a separate container and mix again thoroughly.

        Insufficient mixing is indicated by streaks forming.

    • Application
      • Application temperature: min. 10 °C max. 30 °C
      • Jointing iron / Filling knife
      • Pot life 60 min
      • Application requirements

        Temperature of the material, air and substrate: from min. +10 °C to max. +30 °C

      • Apply the material to the prepared joints using a suitable tool.

         

        The surface of the tiles, slabs or glass blocks must then be pre-washed with warm water and a viscose sponge so that no excess material can cure on it. Then rinse with a viscose sponge and warm water.

    • Application instructions
      • As a general principle, higher temperatures will reduce and lower temperatures will increase the times stated.

        The substrate temperature should not fall below +10 °C during application and curing.

        When coating continuous surfaces, only use materials with the same batch number as slight differences in colour, gloss and texture may occur.

        The stability of the material can be increased by adding a suitable thixotropic agent (e.g. WHG TX).

        Repairs and finishing work on existing joints lead to a visible transition in appearance and structure.

    • Working tools / cleaning
      • Jointing iron / Filling knife
      • Plastic, rubber or Japanese spatula, mixing device, commercial viscose sponge, epoxy jointing board (tree disc).

      • Wash tools and any splashed material with water immediately and while wet.

        Cured material can only be removed mechanically.

    • Storage / shelf life
      • Store frost-free
      • Shelf-life 12 months
      • If stored unopened in the original container and kept cool, dry and protected from frost, min. 12 months (component A)/min. 24 months (component B).

    • Usage
      • See application examples!

    • Application examples
      • Material application rates for earthenware
        Dimensions
        Joint width
        Joint depth
        Application rate

        10 x 10 cm

        (Joint length approx. 20 running m/m²)


        5 mm
        5 mm
        0.70 kg/m²
        8 mm
        1.12 kg/m²
        10 mm
        1.40 kg/m²
        8 mm
        8 mm
        1.79 kg/m²
        10 mm
        2.24 kg/m²

        10 x 20 cm

        (Joint length approx. 15 running m/m²)

        5 mm
        5 mm
        0.52 kg/m²
        8 mm
        0.52 kg/m²
        10 mm
        1.05 kg/m²
        8 mm
        8 mm
        1.34 kg/m²
        10 mm
        1.68 kg/m²
        13 mm
        2.18 kg/m²
        10 mm
        10 mm
        2.10 kg/m²
        13 mm
        2.73 kg/m²



        Material application rates for earthenware
        Dimensions
        Joint width
        Joint depth
        Application rate

        15 x 15 cm

        (Joint length approx. 13 running m/m²)

        2.5 mm
        6.5 mm
        0.29 kg/m²
        5 mm
        5 mm
        0.45 kg/m²
        8 mm
        0.72 kg/m²
        10 mm
        0.90 kg/m²
        8 mm
        8 mm
        1.16 kg/m²
        10 mm
        1.45 kg/m²
        13 mm
        1.89 kg/m²
        10 mm
        10 mm
        1.82 kg/m²
        13 mm
        2.63 kg/m²
        15 x 20 cm (Joint length approx. 12 running m/m²)
        2.5 mm
        6.5 mm
        0.27 kg/m²
        20 x 20 cm (Joint length approx. 10 running m/m²)
        2.5 mm
        6.5 mm
        0.22 kg/m²
        20 x 25 cm (Joint length approx. 9 running m/m²)
        2.5 mm
        6.5 mm
        0.20 kg/m²
        28 x 28 cm (Joint length approx. 7 running m/m²)
        4 mm
        6.5 mm
        0.25 kg/m²

    • General information
      • Unless otherwise specified, all of the values and application rates given above have been determined under laboratory conditions (20 °C) using standard colours. Slight deviations from these values may arise if the product is worked with on site.

        Epoxy resins are generally not colourfast when exposed to UV light or weather.

        Further notes on working, system construction and maintenance of the listed products can be found in the latest Technical Data Sheets and the Remmers system recommendations.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For professional users only!

        Further information concerning safety during transport, storage and handling as well as on disposal and ecology can be found in the latest Safety Data Sheet.

    Possible system products