• Gebindeabbildung BIT 1K (basic)

    Article No. 087210

    BIT 1K [basic]

    Solvent-free, polymer-modified, single-component bituminous thick coating with polystyrene

    Variant
    0872 | BIT 1K
    Packaging unit

    Product specifications

    On delivery

    Base Polymer-bitumen emulsion with polystyrene
    Density of ready-to-use mixture Approx. 0.75 kg/l
    Time until thoroughly dry
    (20 °C/70% relative humidity)
    Approx. 72 hours (depending on weather conditions and the thickness of the fresh layer, the time given may be shorter or longer.)
    Consistency Paste-like, thixotropic
    Crack-bridging ≥ 2 mm
    Cross-slit pressure test (DIN 15820) Passed
    Dry residue Approx. 80 vol%

    The stated values represent typical product characteristics and are not to be construed as binding product specifications.

    Field of application

    • For use on floors/walls indoors
    • Waterproofing of new and old buildings with ground contact
    • Waterproofing in load cases 4, 5 and 6 according to DIN 18195 (withdrawn as of July 2017)
    • Water effect classes W1.1-E, W1.2-E, W2.1-E, W3-E and W4-E according to DIN 18533
    • Retrofit waterproofing of buildings according to WTA Code of Practice 4-6
    • Waterproofing of plinths and base points

    Properties

    • Water-based
    • Solvent-free
    • Water pressure tight
    • Highly flexible, elastic and crack-bridging
    • Radon-tight (verified through testing)
    • Preparation
      • Substrate requirements

        Even-surfaced, mineral substrate.

        Clean, dust-free and capable of supporting a load.

        Matt damp surfaces are permitted.

        If necessary, provide damp proofing.

      • Preparations

        Remove projecting seams and mortar remains.

        Break off or slope corners and edges.

        Smooth out coves using a suitable mineral mortar.

        Close indentations > 5 mm using a suitable mineral material.

        Prime mineral substrates with Kiesol (1:1 in water) or Protective Coating (1:10 in water).

        If the substrate requires reinforcement (restoration), prime using Kiesol (1:1 with water).

        A scratch coat should be applied to weakly absorbent substrates using the product in order to prevent blisters.

    • Application
      • Airless/airmix spraying / trowel application
      • Application temperature: min. 5 °C max. 35 °C
      • Application requirements

        Temperature of the material, air and substrate: from min. +5 °C to max. +35 °C

      • Ready to use, straight from the container.

        Remove any dried material adhering to the edge of the bucket.

        Apply the material in two layers on the previously prepared substrate.

        If a reinforcement fabric is required, embed into the first waterproofing layer.

    • Application instructions
      • Do not apply any further sealing layers until the previous layer has hardened sufficiently.

        Protect freshly coated surfaces from rain, direct sunlight, frost and condensation.

        Protect dry sealant from mechanical damage and UV radiation.

        Please contact Remmers Technical Service (phone +49 5432 83-153) before applying with machine processing.

    • Working tools / cleaning
      • Airless/airmix spraying / trowel application
      • Scoop (4103), smoothing trowel (4004), float (4000), suitable spraying equipment

      • Clean tools immediately after use with water.

        Remove dried-on material using V 101 Thinner (0978).

    • Storage / shelf life
      • Shelf-life 6 months
      • Store frost-free and cool / protect for moisture / close containers
      • If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 6 months.

    • Usage
      • Approx. 1.3 l / mm thick layer / m²
      • Approx. 1.3 l/m²/mm dry layer thickness For details see the application rate table under Application examples

    • Application examples
      • Water effect class 
        (according to DIN 18533)

        Load class 
        (according to DIN E 18195)

        witdhrawn as of July 2017

        Dry layer thickness 
        (mm)
        Wet layer thickness
        (mm)
        Application quantity
        (l/m²)
        Spreading capacity 30 l
        (m²)
        W1-E
        Ground moisture and non-pressing water
        Load case 4
        Ground moisture and non-pressing water
        ≥ 3 approx. 4.0 approx. 4.0 approx. 7.5
        W2.1-E
        Moderate action of pressing water (immersion depth ≤ 3m)
        Load case 6
        Standing seepage water
        ≥ 4 approx. 5.0 approx. 5.0 approx. 6.0
        W3-E
        Non-pressing water on earth-covered ceilings
        Load case 5
        Non-pressing water on earth-covered ceilings
        ≥ 4 approx. 5.0 approx. 5.0 approx. 6.0
        W4-E
        Splashing water at wall base and capillary water in and beneath walls in contact with the ground
        Base waterproofing in wall positioning area ≥ 3 approx. 4.0 approx. 4.0 approx. 7.5
        Layer thickness excess according to DIN 18533

        du = scratch coat application rate approx. 0.5 l/m² (depending on substrate)
        dv = - not necessary with float 
                - without float, application rate approx. 0.7 l/m² (dmin = 4 mm)

    • General information
      • Deviations from applicable regulations must be agreed separately.

        The relevant test certificates must be observed when planning and carrying out work.

        The special agreements as well as test certificates can be downloaded online at www.remmers.com.

    • Disposal instructions
      • Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.

    • Safety / regulations
      • For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.